Secured Trading Service

Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet

Zhejiang FUXIA Medical Technology Co., Ltd.
  • Audited Supplier
  • 13 yrs

Contact Supplier

Product Highlights

  • Advanced HEPA Filtration: Dual HEPA filters with 99.995% efficiency at 0.3 um particles, ensuring ISO 5 Class 100 cleanliness in the work zone.
  • Durable Construction: 304 stainless steel work zone with anti-bacterial powder-coated exterior, easy to clean and resistant to chemical disinfectants.
  • Optimized Airflow System: 70% air recirculation and 30% exhaust design with balanced inflow velocity (0.53 m/s) and downflow velocity (0.33 m/s) to prevent aerosol escape.
  • UV Sterilization: Built-in UV lamp with programmable timer and safety interlock.
  • DOP Detection Port: Equipped with a built-in differential pressure gauge for filter integrity testing.
  • Waterproof Power Socket: Work area includes waterproof socket and sewage interface for operator convenience.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet

Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet pictures & photos
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet pictures & photos
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet pictures & photos
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet pictures & photos
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet pictures & photos
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet pictures & photos
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
  • Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
  • Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
    Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
  • Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
    Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
  • Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
    Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
  • Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
    Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
  • Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
    Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
  • Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
    Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet

Find Similar Products

Product Description

Product Description
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Product Features
1. Air curtain isolation design to prevent internal and external cross contamination, 30% of the airflow is discharged to 70% of the internal circulation, negative pressure vertical laminar flow, no need to install pipes.
2. The glass door can be moved up and down, which can be positioned arbitrarily, easy to operate, and can be completely closed for sterilization, and the positioning height limit alarm prompts.
3. The power output socket in the work area is equipped with a waterproof socket and a sewage interface to provide great convenience for the operator 
4. There is a HEPA filter at the exhaust to control emission pollution. 
5. The working environment ensures no pollution and leakage. It adopts high-quality 304 stainless steel, which is smooth, seamless, and has no dead ends. It can be easily and thoroughly disinfected, and can prevent the erosion of corrosive agents and disinfectants. 
6. It adopts LCD panel control, built-in UV lamp protection device, the UV lamp can only run when the front window and fluorescent lamp are closed, and has UV timing function.
7. 10° inclination angle, in line with human body design concept.
Specification
Model 
BSC-1000IIA2 compact
BSC-1000IIA2
BSC-1300IIA2
BSC-1600IIA2
Airflow system
70% air recirculation, 30% air exhaust
Cleanliness 
HEPA: ISO 5 (Class100)
Number of colonies
≤0.5pcs/dish·hour (Φ90mm culture plate)
Wind speed
Average suction wind speed: ≥0.55±0.025m/s
Average descending wind speed: ≥0.3±0.025m/s
Filtration Efficiency
HEPA of borosilicate glass fiber material: ≥99.995%, @0.3μm
Noise
≤65dB(A)
Illumination
≥800Lux
Power supply
AC single phase 220V/50Hz
Internal Size (mm)        W*D*H
840*650*620
1040*650*620
1340*650*620
1640*650*620
External Size (mm)         W*D*H
1000*800*2100
1200*800*2100
1500*800*2100
1800*800*2100
HEPA specification and quantity
780*490*50*1
520*380*70*1
980*490*50*1
520*380*70*1
1280*490*50*1
820*380*70*1
1580*490*50*1
1120*380*70*1
Specification and quantity of fluorescent lamp/UV lamp
8W*2/20W*1
12W*2/20W*1
20W*2/30W*×1
20W*2/40W*×1
Detailed Photos
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Packing & Delivery
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Certifications
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Company Profile
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet
Laboratory Biological Safety Cabinet Class II A2 Type Microbiological Safety Cabinet

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR253622". Items marked "verified" are certified.

Watch Video
Watch Video
Zhejiang FUXIA Medical Technology Co., Ltd.
Zhejiang FUXIA Medical Technology Co., Ltd.
Zhejiang FUXIA Medical Technology Co., Ltd.
Zhejiang FUXIA Medical Technology Co., Ltd.
Zhejiang FUXIA Medical Technology Co., Ltd.
Zhejiang FUXIA Medical Technology Co., Ltd.
Zhejiang FUXIA Medical Technology Co., Ltd.
Zhejiang FUXIA Medical Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No. 8-1, Houhengjiang Road, Xintunnan Village, Daoxu Town, Shangyu, Shaoxing, Zhejiang, China
verified Number of Employees
51
verified Registered Capital
58,800,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port
verified Minimum Order Quantity
1 set

Our Production Capability & Technical Expertise

Main Products
Biosafety Cabinet, Biological Safety Cabinet, Fume Hood, Pass Box, Muffle Furnace, Air Shower, Dying Oven, Clean Bench, Laminar Flow Cabinet, Weighing Booth
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
3 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2010-08-23
Main Markets
North America, South America, Africa, Mid East
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
Yes

FAQ

What is a Class II Type A2 Biological Safety Cabinet?
A Class II Type A2 Biosafety Cabinet (BSC) is a ventilated enclosure designed to provide three levels of protection: personnel protection (from harmful aerosols), product protection (from external contamination), and environmental protection (through HEPA filtration). It recirculates 70% of the air through HEPA filters and exhausts 30% to the room, making it suitable for Biosafety Level 1, 2, and 3 laboratories working with low-to-moderate risk biological agents.
What sizes are available?
Standard models are available in 4 ft (1200 mm), 5 ft (1500 mm), and 6 ft (1800 mm) widths. Custom dimensions can also be manufactured upon request. Please specify the number of operators (single, dual, or triple) when inquiring.
What is the difference between Class II A2 and Class II B2?
The key difference is the exhaust ratio. A2 cabinets recirculate 70% of air and exhaust 30% into the room. B2 cabinets are hard-ducted and exhaust 100% of air outdoors. A2 is the most common type for microbiology, cell culture, and pharmaceutical applications. B2 is required when working with volatile toxic chemicals or radionuclides in addition to biological agents.
Which HEPA filter is used?
Standard configuration includes dual HEPA filters with 99.995% efficiency at 0.3 um particles. The work zone achieves ISO Class 5 (Class 100) cleanliness, equivalent to a cleanroom environment. Filter life indicators and replacement alarms are built into the control system.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now