Bsc-1300iib2 Medical Equipment Biological Safety Cabinet
Clean biological safety cabinet is necessary in animalcule lab, especially in the condition needing protection measure, such as medicine, pharmacy, scientific research and so on. Main characters
1 It accords with physical engineering principle, 10° Inclination design, so the operating feel is more excellent.
2 Air insulation design to avoid cross pollution inside and outside air circulation within100% exhaust, vertical laminar negative pressure.
3 Equipped with spring up/down movable door in the front and back of work bench, flexible and convenient to locate
4 Equipped with special filter on ventilation to keep vented air conforming to national standard.
5 Contact switch adjusts voltage to keep wind speed in working area in ideal state all the time.
6 Operate with LED panel.
7 The material of the work area is 304 stainless steel.
Parameter / model BSC-1000IIB2 BSC-1300IIB2 BSC-1600IIB2
Cleaning level 100 Level(USA Federal Standard 209E)≥ 0.5um Granulae≤ 3.5per liter
Descending wind speed ≥ 0.35m/s
Wind speed in ≥ 0.55m/s
Noise ≤ 58dB(A)
Half ventilation peak value ≤ 3µ M
Power supply/Max. Power consumption AC220V/50Hz/1KW
Biological safety Personnel protection: Impact type sampler: CFU≤ 10; Narrow slot type sampler: CFU≤ 5
Product protection: All sampling vessels: CFU≤ 5
Cross contamination protection: All double dishes: CFU≤ 2
Working area 1000*650*580 1300*650*580 1600*650*580
Overall dimension 1200*750*1950 1500*750*1950 1800*750*1950
Specification of air-supply filter 955*545*50*1 1290*554*50*1 1590*554*50*1
Specification and number of fluorescent lamp or UV lamp 20W*2/20W*1 30W*2/30W*1 30W*2/30W*2
Illumination ≥ 650LX ≥ 650LX ≥ 650LX
Weight(kg) 300 340 380
Suit Single Double Double
Model Parameter |
BSC-1000IIB2 |
BSC-1300IIB2 |
BSC-1600IIB2 |
Airflow system |
100% air exhaust |
Cleanliness grade |
HEPA: ISO 5 (Class100) |
Number of colonies |
≤0.5pcs/dish·hour (Φ90mm culture plate) |
Wind speed |
Average suction wind speed: ≥0.55±0.025m/s Average descending wind speed: ≥0.3±0.025m/s |
Filtration Level / Filtration Efficiency |
HEPA of borosilicate glass fiber material: ≥99.995%, @0.3μm Optional ULPA: ≥99.9995% |
Noise |
≤65dB(A) |
Illumination |
≥800Lux |
Vibration half peak |
≤5μm |
Power supply |
AC single phase 220V/50Hz |
Maximum power consumption |
500W |
600W |
700W |
Weight |
210KG |
250KG |
270KG |
Internal Size (mm) W*D*H |
1040*650*620 |
1340*650*620 |
1640*650*620 |
External Size (mm) W*D*H |
1200*800*2270 |
1500*800*2270 |
1800*800*2270 |
High efficiency filter specification and quantity |
980*490*50*1 520*380*70*1 |
1280*490*50*1 820*380*70*1 |
1580*490*50*1 1120*380*70*1 |
Specification and quantity of fluorescent lamp/UV lamp |
20W*2/20W*1 |
30W*2/30W*1 |
30W*2/30W*1 |